POSNBAT5
5.12 kWh
- Nominal voltage
- 51.2 V
- Capacity
- 100 Ah
- DC output
- 5.12 kW
- Installation
- Wall or floor
48 V-CLASS ENERGY STORAGE
Selecting a battery for a 48 V-class hybrid or off-grid inverter? Compare the 44.8–57.6 V battery operating range with your inverter specifications, then check current limits and the BMS protocol.
MODEL COMPARISON
Check the maximum charge and discharge currents for the chosen model. CAN and RS485 are communication interfaces; protocol compatibility depends on the exact inverter and firmware.
POSNBAT5
POSNBAT10
POSNBAT16
SERIES SPECIFICATIONS
The shared communication, protection and operating platform simplifies early comparison while model-level energy and power remain distinct.
| Specification | POSNBAT5 | POSNBAT10 | POSNBAT16 |
|---|---|---|---|
| Nominal energy | 5.12 kWh | 10.24 kWh | 16.08 kWh |
| Usable energy at 90% DoD | 4.61 kWh | 9.22 kWh | 14.47 kWh |
| Nominal capacity | 100 Ah | 200 Ah | 314 Ah |
| Max. charge / discharge | 100 A / 100 A | 150 A / 200 A | 200 A / 200 A |
| Continuous DC output | 5.12 kW | 10.24 kW | 10.24 kW |
| Installation | Wall or floor | Floor standing | Floor standing |
For the 100 Ah POSNBAT5, compare the battery’s 44.8–57.6 V operating range and 100 A maximum charge and discharge currents with the inverter’s battery settings. A CAN or RS485 socket alone does not establish BMS compatibility. Send the inverter model, firmware version and planned battery count so POSON can check the combination.
Check my inverter against POSNBAT5 ↗Series increases voltage. Parallel increases capacity at the same nominal voltage. POSON specifies parallel expansion for the POSNBAT range. For example, two matched POSNBAT5 units in an approved parallel configuration give 200 Ah and 10.24 kWh nominal at 51.2 V. A single POSNBAT10 offers the same nominal energy in one enclosure.
The series is specified for up to 16 units in parallel, subject to the inverter protocol, communication and protection design. Confirm the permitted count for your project with POSON.
Check the POSNBAT5 electrical data ↗
APPLICATION CONTEXT
A 51.2 V low-voltage LFP battery can store surplus rooftop solar or supply selected backup circuits through a compatible inverter. Off-grid systems also need enough generation and reserve energy for periods without sun.
V2.1 inverter: CGI design concept · Engineering validation pending
COMMUNICATION & SYSTEM FIT
Do not assume brand compatibility from voltage alone. Share the exact inverter model and protocol requirement before ordering.
DISTRIBUTOR DECISION PATH
Use the model pages to compare specifications, download the series datasheet, and submit market, quantity and inverter requirements in one enquiry.